Projects

Sealion Shipping Limited

Annual inspections performed of the 30T & 250T.Both cranes are installed on the TOISA PERSEUS which was located in Abu Dhabi during the... Read More...
Aannemingsbedrijf A. Tuin Den Helder BV

Maintenance Petrus Paulus Church, Den Helder - Replacement of damaged tile, located on the fifth row from the top. - Re-arrangement of piece of... Read More...
Centrica Energy

Eddy Current and TCVT crane inspection- Centrica-WindermereDHC 6/1300 Offshore Crane were inspected using Close Visual and Eddy Current Inspection... Read More...
Final Fixation Conductor pipe- K1A

Final fixation of the conductor pipe with centralizers at main deck and spider deck level by the use of rope access as rigging.   Read More...
GDF SUEZ E&P Nederland B.V.

Eddy Current inspection Vent Stack lifeboat structure - L5-FA-1Eddy Current inspection: - Crane Pedestal- Vent Stack- Free Fall Life Boat support... Read More...
Maersk Drilling

For the installation of the new supporting for the cement line the insulation on the roof of the engine roof was temporary removed by the use of the... Read More...
Noble Drilling

Inspection BOP crane & pipe handling- Hans DeulInspection of varios parts of the BOP overhead crane were inspected by the use of rope access. Read More...
Noble Drilling, Various Annual Crane Inspections

Various Annual Crane Inspections: - Noble George Sauvageau - Noble Homer Ferrington - Noble Julie Robertson - Noble Hans Deul - Noble Scott Marks -... Read More...
Temporary Fixation conductor pipe - K1A

Total E&P Nederland B.V. Temporary Fixation conductor pipe - K1A By the use of rope access as rigging: - Secure a conductor pipe at main deck... Read More...
Total E&P Nederland B.V.

After load testing of the life boat structures and offshore cranes, Eddy Current inspections (NDT) was performed on all welds of the primary... Read More...

Mr. Mathieu Vaandrager, who is the managing director of Crane Inspection Services, was unanimously elected as the new chairman of the RAC Benelux (Regional Advisory Committee). This Identification Committee in Rope Access consists only of qualified IRATA company members (Industrial Rope Access Trade Association).

To continue rope access work as safely as possible, the RAC meets several times a year to discuss any safety issues that may arise in the industry. If required, they then send any recommendations on to the IRATA headquarters, so that the guidelines can be adjusted.

Mr. Mathieu Vaandrager succeeds Jeroen Offermans of the company Ascent Safety BV.



Inspections,